Difference between revisions of "InfoCenter Personal"

imported>NelsonJenkins
imported>NelsonJenkins
 
(One intermediate revision by the same user not shown)
Line 6: Line 6:
 
| launch year      = 2012
 
| launch year      = 2012
 
| company          = [[Gentek]]
 
| company          = [[Gentek]]
| available        = Marketplace & In-World
+
| available        = Upgraded to [[InfoCenter]]
| url              = '''[https://marketplace.secondlife.com Marketplace Listing]'''
 
 
}}
 
}}
  
 
The '''InfoCenter Personal''' is a smaller version of the [[InfoCenter Highway]]. It is a 24-character, 1-line electronic text display. It was designed to be used in commercial storefronts to attract attention and relay preprogrammed sale information; however, it can be used anywhere. Additionally, it can be controlled remotely using a server box which can control multiple signs at the same time. It was released in July 2012 along with the [[InfoCenter Highway]].
 
The '''InfoCenter Personal''' is a smaller version of the [[InfoCenter Highway]]. It is a 24-character, 1-line electronic text display. It was designed to be used in commercial storefronts to attract attention and relay preprogrammed sale information; however, it can be used anywhere. Additionally, it can be controlled remotely using a server box which can control multiple signs at the same time. It was released in July 2012 along with the [[InfoCenter Highway]].
 +
 +
'''This page covers the InfoCenter Personal v2. For v3 and above, see [[InfoCenter]].''' Because of the complexity in the new system and licensing restrictions, v3 is not a free update.
  
 
==Setup==
 
==Setup==
Line 34: Line 35:
 
* [b]Text[/b] - Blue
 
* [b]Text[/b] - Blue
 
* [p]Text[/p] - Purple
 
* [p]Text[/p] - Purple
 +
* [a]Text[/a] - Amber
 
* [x]Text[/x] - Rainbow
 
* [x]Text[/x] - Rainbow
 
Text not in these color formatting brackets is rendered white. Multiple colors can be used in the same line.
 
Text not in these color formatting brackets is rendered white. Multiple colors can be used in the same line.
Line 53: Line 55:
 
* To set a display to a single frame of text without a server, click it and select "Custom Text". This works the same as the server-side function.
 
* To set a display to a single frame of text without a server, click it and select "Custom Text". This works the same as the server-side function.
 
* To clear a display, click it and select "Clear Text". You will want to change the display ID to something unused if you have a server running on the same ID, or else it will keep showing text.
 
* To clear a display, click it and select "Clear Text". You will want to change the display ID to something unused if you have a server running on the same ID, or else it will keep showing text.
 +
 +
==InfoCenter API==
 +
The InfoCenter Personal can be controlled using the following LSL command:
 +
llRegionSay(-203040506,llDumpList2String(["ICSET",displayID,text],"#$"));
 +
So, for example:
 +
llRegionSay(-203040506,llDumpList2String(["ICSET","Default","This is [g]green[/g] text"],"#$"));
 +
Formatting codes can be used. This is similar to using the Custom Text option directly on the display. Note that this command is only for the InfoCenter Personal; the [[InfoCenter Highway]] has a different format.
  
 
{{Gentek}}
 
{{Gentek}}

Latest revision as of 20:38, 14 November 2014

InfoCenter Personal
VendorImage5 - InfoCenter Personal.jpg

InfoCenter Personal vendor image.
Creator Nelson Jenkins
Launch year 2012
Company Gentek
Availability Upgraded to InfoCenter

The InfoCenter Personal is a smaller version of the InfoCenter Highway. It is a 24-character, 1-line electronic text display. It was designed to be used in commercial storefronts to attract attention and relay preprogrammed sale information; however, it can be used anywhere. Additionally, it can be controlled remotely using a server box which can control multiple signs at the same time. It was released in July 2012 along with the InfoCenter Highway.

This page covers the InfoCenter Personal v2. For v3 and above, see InfoCenter. Because of the complexity in the new system and licensing restrictions, v3 is not a free update.

Setup

  1. Rez a display and a server.
  2. Open the server's inventory and edit the _config notecard. Change @ID's value to something memorable - for example, if you have a display in your store window, set it to "Store Window".
  3. Edit the text. See "Formatting" below for more information on this. Then, save the notecard.
  4. Click the display and select "Set Disp ID". Then, enter the display ID you set in step 1.

Formatting

The general format for each frame of text is the following:

>3

The number of seconds for that frame. This will start a new frame, and must be preceded by the > character. Can be an integer (3) or a floating-point decimal (5.9). Do not include this line when setting custom text through the menu.

This is [g]green[/g] text

One line of text, maximum 24 characters excluding formatting codes.

Then, repeat for each frame. The default _config notecard has an example.

The InfoCenter supports the following formatting codes, used similarly to BBCode:

  • [r]Text[/r] - Red
  • [o]Text[/o] - Orange
  • [y]Text[/y] - Yellow
  • [g]Text[/g] - Green
  • [b]Text[/b] - Blue
  • [p]Text[/p] - Purple
  • [a]Text[/a] - Amber
  • [x]Text[/x] - Rainbow

Text not in these color formatting brackets is rendered white. Multiple colors can be used in the same line.

Note that these formatting codes are excluded from the maximum letter count per line.

Use the caret (^) for a full box character.

Additional Features

You can give other people access to the below configuration menus with the @ACCESS, @WHITELIST, and @BLACKLIST values. They are explained in the notecard.

The server comes with these menu functions:

  • To stop text output, click it and select "Stop Text". This won't clear the text.
  • To clear text on all displays with the same ID, click it and select "Clear Text".
  • To set custom text without editing the notecard, click it and select "Custom Text", then put text in the input box as you would in the notecard. However, do not include the time command (e.g. >3) - just include the 1 line of text with formatting.
  • To resume automatic text, click it and select "Start Text".

The display comes with some menu functions too, which can be accessed by anyone with access to the server with the same ID:

  • To set a display to a single frame of text without a server, click it and select "Custom Text". This works the same as the server-side function.
  • To clear a display, click it and select "Clear Text". You will want to change the display ID to something unused if you have a server running on the same ID, or else it will keep showing text.

InfoCenter API

The InfoCenter Personal can be controlled using the following LSL command:

llRegionSay(-203040506,llDumpList2String(["ICSET",displayID,text],"#$"));

So, for example:

llRegionSay(-203040506,llDumpList2String(["ICSET","Default","This is [g]green[/g] text"],"#$"));

Formatting codes can be used. This is similar to using the Custom Text option directly on the display. Note that this command is only for the InfoCenter Personal; the InfoCenter Highway has a different format.